<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-13 01-22-14
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
6.2 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 64 kHz 6357 1,1798
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 4,98 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 64 kHz MIN: 15 kHz % above 76 kHz: 1,1798 Acquired: 2024/12/13 1.21.11 Total samples: 6357 Equivalent time: 0:05:17 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 6,4 dBr MIN: 3,5 dBr AVE: 4,98 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2024/12/13 1.21.10) 01.08 01.10 01.12 01.14 01.16 01.18 01.20 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]